The plasma point welding device is used for sheet metal up to 2.5mm (PSW 350TL) or 3.5mm (PSW 500TL).

Mainly used materials for plasma spot welding are stainless steels, steels, titanium, zirconium and copper.

TECHNICAL DETAILS

  • high procedural security
  • high degree of automation
  • high productivity due to high welding speed

Applicable Welding Methods
  • PLASMA Spot Welding
Range of suitable material thickness (Plasma spot welding)~ 0.5 – 4 mm
Automation
  • Capable for automation
Operating modesDC
Supply Voltage3 × 400 V ±15 % 50/60Hz
Phase3 Phase
Power connection4 × 32 A CCE plug, 6 mm²
Adjustment range welding current5 – 500 A
Adjustment range TIG mode5 – 500 A
Adjustment range MMA mode5 – 450 A
CoolingLiquid
Degree of protectionIP 21 S
Length1120 mm
Width450 mm
Height935 mm
Weight112 kg
Features
  • Power source with HF-ignition
  • Touch Screen 5,4"
  • USB interface
  • Ethernet interface
  • Integrated welding program memory
  • Integrated cooling
  • Integrated monitoring / gaging of cooling medium
  • Integrated electronic gas regulation (PGR)

    electr. plasma control, range 0,1 – 5 l/min

  • Integrated control of wire feeder / powder feeder
    (MCC)

    Motor control card to drive from an SBI wire case.

    All Compac 6 application-rated, six-inch starters use TeSys D-Line contactors and GJ frame Mag-Gard adjustable instantaneous trip breakers (UL Listed for 100,000 A at 480 V short circuit rating).

    Compac 6 application-rated six-inch starters will mount in 20 in. wide by 15 in. or 20 in. deep sections. Select application rated units based on system voltage and motor full load amps.

  • Integrated control of wire feeder / powder feeder
    (MCU-M)
  • Integrated control of wire feeder and free wheel encoder
    (MCU-MI)
  • Integrated control of 2 wire feeders and free wheel encoder
    (MCU-MSI)
  • Integrated automation interface
  • Software for external controlling via computer
    (diagnostics, parameter setup, documentation)
  • Mobility by wheels
  • Parking area for 20l gas bottle
  • Flowmeter shielding gas
  • Flowmeter plasma gas
  • Remote Control RC-S
  • HPP1 - High Pressure Pump (1 circuit)
  • HPP2 - High Pressure Pump (2 circuits)
  • Plate Heat Exchanger
Automation Interface “Tiny”
  • Included
Digital Inputs2 × 24 V
Digital Outputs3 × 24 V
Analog Inputs2 × 0 – 10 V
Analog Outputs2 × 0 – 5 V
CAN Bus (SBI protocol)
  • Included
Automation Interface “AS/AD Basic”
  • Included
Digital Inputs10
Digital Outputs10
Analog Inputs4
Analog Outputs4
KTY Input1
CAN Interface
  • Included
Connection cable5m
Capability for / availability of specific bus interfaces
  • Included